I1CF-Q8801P-C3U2/M

Installation type:  Flush

Detection distance:  1mm

Output polarity:  PNP NC

voltage:  10-30VDC

Connection mode:  2 M cable

Shell material:  Nickle plated brass

Other notes:  

 


Technical data  
Installing Flush
Sensing distance  1 mm
 LED display  Yes
Operation voltage  10-30VDC
Ripple  <10%
 No load current  <10mA
Max load current  200mA
Leakage current  <0.01mA
Voltage drop  <1.5v
Frequency  2KHZ
Response time  0.1ms
Hysteresis  <15%sr
Repeat accuracy  <1.0%sr
 Protection category  IP67
Operating temperature  -25℃----+70℃
Temperature drift  <10%sr
 Short circuit protection/reverse polarity protection Yes
 Overload trip point  220mA
Material active face  PBT
Connecting way  2 M cable
Size  
Connecting Diagram  

 

 