Model | Installation type | Detection distance | Output polarity | Voltage | Connection mode | Shell material | Other instructions |
HC1CN-M1815N-O3U2-120 | Non-flush | 2-15mm | NPN NO | 10-30VDC | 2 M cable | Nickel Plated Brass | Operation temperature:-25℃-+120℃ |
HC1CN-M1815N-C3U2-120 | Non-flush | 2-15mm | NPN NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+120℃ |
HC1CN-M1815P-O3U2-120 | Non-flush | 2-15mm | PNP NO | 10-30VDC | 2 M cable | Nickel Plated Brass | Operation temperature:-25℃-+120℃ |
HC1CN-M1815P-C3U2-120 | Non-flush | 2-15mm | PNP NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+120℃ |
HC1CN-M1815P-S4U2-120 | Non-flush | 2-15mm | PNP NO+NC | 10-30VDC | 2 M cable | Nickel Plated Brass | Operation temperature:-25℃-+120℃ |
HC1CN-M1815N-S4U2-120 | Non-flush | 2-15mm | NPN NO+NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+120℃ |
HC1CN-M1815N-O3U2-150 | Non-flush | 2-15mm | NPN NO | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+150℃ |
HC1CN-M1815N-C3U2-150 | Non-flush | 2-15mm | NPN NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+150℃ |
HC1CN-M1815P-O3U2-150 | Non-flush | 2-15mm | PNP NO | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+150℃ |
HC1CN-M1815P-C3U2-150 | Non-flush | 2-15mm | PNP NO | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+150℃ |
HC1CN-M1815P-S4U2-150 | Non-flush | 2-15mm | PNP NO+NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+150℃ |
HC1CN-M1815N-S4U2-150 | Non-flush | 2-15mm | NPN NO+NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+150℃ |
HC1CN-M1815N-O3U2-180 | Non-flush | 2-15mm | NPN NO | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+180℃ |
HC1CN-M1815N-C3U2-180 | Non-flush | 2-15mm | NPN NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+180℃ |
HC1CN-M1815P-O3U2-180 | Non-flush | 2-15mm | PNP NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+180℃ |
HC1CN-M1815P-C3U2-180 | Non-flush | 2-15mm | PNP NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+180℃ |
HC1CN-M1815P-S4U2-180 | Non-flush | 2-15mm | PNP NO+NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+180℃ |
HC1CN-M1815N-S4U2-180 | Non-flush | 2-15mm | NPN NO+NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-25℃-+180℃ |
LC1CN-M1815N-O3U2-30 | Non-flush | 2-15mm | NPN NO | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-30℃-+70℃ |
LC1CN-M1815N-C3U2-30 | Non-flush | 2-15mm | NPN NC | 10-30VDC | 2M Cable | Nickel Plated Brass | Operation temperature:-30℃-+70℃ |
2nd Fl.,Building 3C,East Zone,Liandong U valley, Majuqiao Town, Tongzhou District, Beijing City, China 101102
sales@bidukelec.com